  Datasheet File OCR Text:
 TFS248F.doc
Version 3.0
15.11.2002
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedance: input: output: 23 C 0 dBm
Filter Specification
TFS 248F
1/5
50 ; unbalanced; no matching network 200 ; balanced, no matching network
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 248 F is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae . The nominal frequency fN is fixed at 248,6 MHz. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Insertion Loss (Reference Level) Nominal Frequency Centre Frequency 3 dB Band width Pass Band Ripple fN 120 KHz Relative Attenuation fN - 238,6 MHz ... fN -29,2 MHz @ fN + 22,8 @ fN + 52,0 @ fN + 74,8 @ fN + 104,0 @ fN + 126,8 MHz MHz MHz MHz MHz
arel a e = amin
typ. Value
2,95 dB 6,44 MHz 4,30 MHz min max
Limit
3,5 dB 248,6 MHz 5,0 MHz 0,5 dB
fN fC
50 55 58 56 55 55 55 -
dB dB dB dB dB dB ns
min. min. min. min. min. min.
45 45 45 45 45 45
dB dB dB dB dB dB
Group Delay GD Group Delay Ripple fN 120 kHz Input Power Level Operating Temperature Range Storage Temperature Range Temperature Coefficient of Frequency
TCf
max. 300,0 ns max. 20,0 dBm
- 20 C ... + 80 C - 40 C ... + 85 C -33,5 ppm/K -
generated: checked / approved:
Construction and Pin Connection (All dimensions in mm)
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice No liability is assumed as a result of their use or application.No rights under any patent accompany the sale of any such product(s) or information.
TFS248F.doc
Version 3.0
15.11.2002
VI TELEFILTER
8 9 10 6 5
Filter Specification
1 2 3 4 5 6 7 8 9 10
TFS 248F
Ground Ground Ground Output Output Ground Ground Ground Input RF Return Input
2/5
S 248F P46
1 3
Datecode
4
1 10 9 8
3 4 5 6
Datecode: Year+week M N P ... 2000 2001 2002
No Matching Network
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice No liability is assumed as a result of their use or application.No rights under any patent accompany the sale of any such product(s) or information.
TFS248F.doc
Version 3.0
15.11.2002
VI TELEFILTER
Stability Characteristics
Filter Specification
TFS 248F
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 1,5 mm or 20g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 3000 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm) W Po Do E F P2 P1 Ao Bo CT : : : : : : : : : : 16 4 0,3 0,1
Do Po
EMBOSSED CARRIER TAPE
P2
1,5 + 0,1 1,75 0,1 7,5 0,1 0,6 2 8 1,5 5,5 7,5 0,1 0,1
COVER TAPE P1 CT Ao F W D1 E
G (min) :
0,1 0,1
Bo
D1(min) :
G
13,5 0,1
W2
Reel (all dimensions in mm): A : 330 16,4 +2 22,4 50 13 +0,5 / -0,2
A C N
W1 : W2 (max) : N (min) C : :
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice No liability is assumed as a result of their use or application.No rights under any patent accompany the sale of any such product(s) or information.
TFS248F.doc
Version 3.0
15.11.2002
VI TELEFILTER
Air reflow temperature conditions
Filter Specification
TFS 248F
4/5
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice No liability is assumed as a result of their use or application.No rights under any patent accompany the sale of any such product(s) or information.
TFS248F.doc
Version 3.0
15.11.2002
VI TELEFILTER
History Version
1.0 2.0 3.0
Filter Specification
TFS 248F
5/5
Reason of Changes
- generate according to customer specification - change of package and stop band rejection - Filter Specification; add of terminating impedance and typ. values
Name Dr. Sabah Dr. Sabah Dr. Sabah
Date 25.09.01 13.09.02 15.11.02
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice No liability is assumed as a result of their use or application.No rights under any patent accompany the sale of any such product(s) or information.